Requirement Details
Electron Ion Collider
P-IR-VAC.12
Requirement details, history, relationships and interfaces associated with requirement P-IR-VAC.12
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 05/16/2025 17:04 | |||
Identifier: | P-IR-VAC.12 | WBS: | 6.06.02.04 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Reviewed | |
Description: | The average vacuum level (after conditioning for >1000Ah) in the IR HSR Rear vac-2 shall be <1x10-10 Torr | ||
Comments: |
Record Date: 05/15/2025 20:34 | |||
Identifier: | P-IR-VAC.12 | WBS: | |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | ||
Description: | The average vacuum level (after conditioning for >1000Ah) in the IR HSR Rear vac-2 shall be <1x10-10 Torr | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | P-IR-VAC.12 | WBS: | 6.06.02.04 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Reviewed | |
Description: | The average vacuum level (after conditioning for >1000Ah) in the IR HSR Rear vac-2 shall be <1x10-10 Torr | ||
Comments: |
Parents | |
F-IR-VAC.03 | The EIC IR central vacuum chamber shall be designed to minimize secondary particle production. |
F-IR-VAC.04 | The EIC IR Vacuum chamber impedance shall be small enough to prevent any undesirable beam dynamic issues and adverse heating of vacuum components, for the beam parameters listed in the MPT [EIC-SEG-RSI-005]. |
F-IR-VAC.05 | The EIC IR vacuum pressure from the IP to ends of the final focusing cryostats shall be low enough to ensure the beam gas background for the experiment after the system has been properly conditioned is acceptable for detector operation. |
Children | |
No children. |
This function not yet implemented.