| Record Date: 11/05/2025 00:56 | |||
| Identifier: | P-IR-MAG-HSR-Q1BPR_SKQ.09.00 | WBS: | 6.06.05.02.01.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet is expected to sustain 30 years of EIC operation under nominal conditions. During these 30 operational years, the magnet is expected to survive the following: 60 thermal cycles, 180 quenches 30000 power cycles. | ||
| Comments: | |||
| Record Date: 09/25/2025 23:10 | |||
| Identifier: | P-IR-MAG-HSR-Q1BPR_SKQ.09.00 | WBS: | 6.06.05.02.01.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet is expected to sustain 20 years of EIC operation under nominal conditions. During these 20 operational years, the magnet is expected to survive the following: 40 thermal cycles, 120 quenches 20000 power cycles. | ||
| Comments: | |||
| Record Date: 09/04/2025 22:58 | |||
| Identifier: | P-IR-MAG-HSR-Q1BPR_SKQ.09.00 | WBS: | 6.06.05.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet is expected to sustain 20 years of EIC operation under nominal conditions. During these 20 operational years, the magnet is expected to survive the following: 40 thermal cycles, 120 quenches 20000 power cycles. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |
This function not yet implemented.