Requirement Details
Electron Ion Collider

P-IR-MAG-HSR-Q1APR.08.02
Requirement details, history, relationships and interfaces associated with requirement P-IR-MAG-HSR-Q1APR.08.02
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 10/30/2025 00:28 | |||
| Identifier: | P-IR-MAG-HSR-Q1APR.08.02 | WBS: | TBD |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Record Date: 09/25/2025 23:10 | |||
| Identifier: | P-IR-MAG-HSR-Q1APR.08.02 | WBS: | 6.06.05.01.01.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Record Date: 08/29/2025 02:42 | |||
| Identifier: | P-IR-MAG-HSR-Q1APR.08.02 | WBS: | 6.06.05.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Record Date: 08/27/2025 00:55 | |||
| Identifier: | P-IR-MAG-HSR-Q1APR.08.02 | WBS: | 6.06.05 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |
This function not yet implemented.