Requirement Details
Electron Ion Collider
P-IR-MAG-HSR-B2PF.03.01
Requirement details, history, relationships and interfaces associated with requirement P-IR-MAG-HSR-B2PF.03.01
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 03/10/2025 16:50 | |||
Identifier: | P-IR-MAG-HSR-B2PF.03.01 | WBS: | 6.06.02.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Reviewed | |
Description: | The harmonic reference radius at which the field quality shall be measured is 20(mm) | ||
Comments: |
Record Date: 02/27/2025 21:31 | |||
Identifier: | P-IR-MAG-HSR-B2PF.03.01 | WBS: | 6.06.02.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Reviewed | |
Description: | The harmonic reference radius at 30 (mm) which the field quality shall be measured is | ||
Comments: |
Record Date: 02/26/2025 19:55 | |||
Identifier: | P-IR-MAG-HSR-B2PF.03.01 | WBS: | 6.06.02.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The harmonic reference radius at 30 (mm) which the field quality shall be measured is | ||
Comments: |
Record Date: 02/24/2025 18:26 | |||
Identifier: | P-IR-MAG-HSR-B2PF.03.01 | WBS: | 6.06.02.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The harmonic reference radius at 40(mm) which the field quality shall be measured is | ||
Comments: |
Record Date: 02/20/2025 18:10 | |||
Identifier: | P-IR-MAG-HSR-B2PF.03.01 | WBS: | 6.06.02.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The field at the reference radius Bref shall be, B(at 23GeV)=TBD(T) ~0.45T B(at 41GeV)=TBD(T) ~0.81T B(at100GeV)=TBD(T) ~1.98T B(at 275GeV)=TBD(T). ~5.46T | ||
Comments: |
Record Date: 02/06/2025 16:54 | |||
Identifier: | P-IR-MAG-HSR-B2PF.03.01 | WBS: | 6.06.02.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The harmonic reference radius Rr shall be 20(mm), centered at (x=0,y=0) mm with respect to the beam axis. | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | P-IR-MAG-HSR-B2PF.3.1 | WBS: | 6.06.02.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The harmonic reference radius Rr shall be The harmonic reference radius Rr shall be 20(mm), centered at (x=0,y=0) mm with respect to the beam axis. . | ||
Comments: |
Parents | |
No parents. | |
Children | |
No children. |
This function not yet implemented.