P-IR-MAG-HSR-B0APF_VC.08.02
Requirement details, history, relationships and interfaces associated with requirement P-IR-MAG-HSR-B0APF_VC.08.02
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 10/30/2025 00:28 | |||
| Identifier: | P-IR-MAG-HSR-B0APF_VC.08.02 | WBS: | TBD |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Record Date: 09/30/2025 00:36 | |||
| Identifier: | P-IR-MAG-HSR-B0APF_VC.08.02 | WBS: | 6.06.04.01.01.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Record Date: 09/25/2025 23:10 | |||
| Identifier: | P-IR-MAG-HSR-B0APF_VC.08.02 | WBS: | 06.06.04.01.01.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Record Date: 09/09/2025 02:09 | |||
| Identifier: | P-IR-MAG-HSR-B0APF_VC.08.02 | WBS: | 6.06.04.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |