Requirement Details
Electron Ion Collider

P-IR-MAG-ESR-Q2ER_SKQ.06.04
Requirement details, history, relationships and interfaces associated with requirement P-IR-MAG-ESR-Q2ER_SKQ.06.04
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 09/25/2025 23:10 | |||
| Identifier: | P-IR-MAG-ESR-Q2ER_SKQ.06.04 | WBS: | 6.06.05.02.01.02.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet current leads cooling shall be capable of removing a maximum total heat load each of 0.5(W) at the cold end while maintaining nominal operating conditions between 3.5(bar) and 4(bar) and below 4.7 (K), and lead cooling flow of: Assuming 100(A) leads, and lead cooling flows required are as follows: For currents below 10(A) · The cooling flow is 0.028 (g/s) For currents up to 10(A), · The cooling flow increases by 0.000031 (g/s)/(A) · Upto the peak current ~100(A). Maximum flow of ~ 0.031(g/s) | ||
| Comments: | |||
| Record Date: 09/15/2025 03:49 | |||
| Identifier: | P-IR-MAG-ESR-Q2ER_SKQ.06.04 | WBS: | 6.06.05.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet current leads cooling shall be capable of removing a maximum total heat load each of 0.5(W) at the cold end while maintaining nominal operating conditions between 3.5(bar) and 4(bar) and below 4.7 (K), and lead cooling flow of: Assuming 100(A) leads, and lead cooling flows required are as follows: For currents below 10(A) · The cooling flow is 0.028 (g/s) For currents up to 10(A), · The cooling flow increases by 0.000031 (g/s)/(A) · Upto the peak current ~100(A). Maximum flow of ~ 0.031(g/s) | ||
| Comments: | |||
| Record Date: 09/04/2025 22:58 | |||
| Identifier: | P-IR-MAG-ESR-Q2ER_SKQ.06.04 | WBS: | 6.06.05.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet current leads cooling shall be capable of removing a maximum total heat load of TBD(W) at the cold end while maintaining nominal operating conditions under TBD(bar) and TBD(K), and vapor cooling flow of TBD(g/s) from TBD(K) to 300(K) | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |
This function not yet implemented.