Requirement Details
Electron Ion Collider
P-IR-MAG-ESR-Q0EF.07.02
Requirement details, history, relationships and interfaces associated with requirement P-IR-MAG-ESR-Q0EF.07.02
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 09/30/2025 00:36 | |||
Identifier: | P-IR-MAG-ESR-Q0EF.07.02 | WBS: | 6.06.07.02.03 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | After a thermal cycle to room temperature, the magnet SHOULD attain the nominal operating current with no quenches and SHALL attain the nominal operating current with no more than 3 quenches. | ||
Comments: |
Record Date: 09/25/2025 23:10 | |||
Identifier: | P-IR-MAG-ESR-Q0EF.07.02 | WBS: | 6.06.03.01.02.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | After a thermal cycle to room temperature, the magnet SHOULD attain the nominal operating current with no quenches and SHALL attain the nominal operating current with no more than 3 quenches. | ||
Comments: |
Record Date: 07/22/2025 21:53 | |||
Identifier: | P-IR-MAG-ESR-Q0EF.07.02 | WBS: | 6.06.03 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | After a thermal cycle to room temperature, the magnet SHOULD attain the nominal operating current with no quenches and SHALL attain the nominal operating current with no more than 3 quenches. | ||
Comments: |
Parents | |
No parents. | |
Children | |
No children. |
This function not yet implemented.