Requirement Details
Electron Ion Collider
F-IR-ESR-LATTICE.7
Requirement details, history, relationships and interfaces associated with requirement F-IR-ESR-LATTICE.7
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 01/27/2025 16:43 | |||
Identifier: | F-IR-ESR-LATTICE.7 | WBS: | 6.06.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The IR electron lattice shall provide space for detectors to tag scattered electrons on the downstream side of the IP (Rear Side). | ||
Comments: |
No archive versions
Parents | |
No parents. | |
Children | |
P-ESR-MAG-Q60.01 | The magnet shall have a single function. |
P-ESR-MAG-Q60.04 | The magnet shall require shunt resistors for beam-based alignment, 5A at 5 GeV. |
P-ESR-MAG-Q60.05 | The magnet shall have a Quadrupole field. |
P-ESR-MAG-Q60.07 | The magnet shall have a normal field rotation. |
P-ESR-MAG-Q60.08 | The pole tip radius of the magnet shall be 40 mm. |
P-ESR-MAG-Q60.12 | The physical magnet length shall be <0.6 m. |
P-ESR-MAG-Q60.13 | The effective magnet length shall be 0.6 m. |
P-ESR-MAG-Q60.16 | The magnet integrated grad field G shall be 11.0 T. |
P-ESR-MAG-Q60.19 | The harmonic reference radius and current at 18 GeV shall be 25 (mm) and 412 (A). |
P-ESR-MAG-Q60.20 | The Field at the reference radius and current at 18 GeV shall be 18.9 (T/m). |
P-ESR-MAG-Q60.21 | The magnet bore field shall require the following multipole content: |
P-ESR-MAG-Q60.21.2 | b2 = 10000 , a2 = N/A |
P-ESR-MAG-Q60.21.3 | b3 = HV +/- 2.2 , a3 = +/- 2 |
P-ESR-MAG-Q60.21.4 | b4 = HV +/- 2.4 , a4 = +/- 0.7 |
P-ESR-MAG-Q60.21.5 | b5 = HV +/- 1.0 , a5 = +/- 0.5 |
P-ESR-MAG-Q60.21.6 | b6 = HV +/- 1.0 , a6 = +/- 0.2 |
P-ESR-MAG-Q60.21.7 | b7 = HV +/- 1.0 , a7 = +/- 0.5 |
P-ESR-MAG-Q60.21.8 | b8 = HV +/- 1.0 , a8 = +/- 0.5 |
P-ESR-MAG-Q60.21.9 | b9 = HV +/- 1.0 , a9 = +/- 0.5 |
P-ESR-MAG-Q60.21.10 | b10 = HV +/- 1.0 , a10 = +/- 0.5 |
P-ESR-MAG-Q60.21.11 | b11 = HV +/- 1.0 , a11 = +/- 0.4 |
P-ESR-MAG-Q60.21.12 | b12 = HV +/- 1.0 , a12 = +/- 0.3 |
P-ESR-MAG-Q60.21.13 | b13 = HV +/- 1.0 , a13 = +/- 0.2 |
P-ESR-MAG-Q60.21.14 | b14 = HV +/- 1.0 , a14 = +/- 0.15 |
P-ESR-MAG-Q60.27 | The magnet shall be designed to specifically constrain the external fringe field to 10 Gauss at 40mm from the RCS beamline. |
P-ESR-MAG-Q60.29 | The magnetic field, center and alignment, within the magnet must be known to within a translational value of +/-50 (um) and a rotational alignment value of +/-0.5(mrad). |
P-ESR-MAG-Q60.31 | The magnet install center and install alignment must be within a translational value of +/-150(um) and a rotational alignment value of +/-0.5(mrad). |
P-ESR-MAG-Q60.46 | The magnet design and verification process shall ensure the final magnet will meet the reliability needs of the EIC over it planned operational life of >20 Years. |
P-ESR-MAG-Q60.32 | The magnet shall have a splitable pole to facilitate the vacuum beam pipe installation. |
P-ESR-MAG-Q60.47 | The magnet shall be designed to operate reliably given the cumulative radiation dose of TBD Rads it will experience over the lifetime of the EIC of >20 Years. |