Requirement Details
Electron Ion Collider
G-HSR.17
Requirement details, history, relationships and interfaces associated with requirement G-HSR.17
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 02/13/2025 19:28 | |||
Identifier: | G-HSR.17 | WBS: | 6.05 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The HSR shall meet the beam parameters specified for different species at injection defined in MPT. [Document#:EIC-SEG-RSI-005] | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | G-HSR.17 | WBS: | 6.05 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The HSR shall meet the beam parameters specified for different species at injection defined inMPT. [Document#:EIC-SEG-RSI-005] | ||
Comments: |
Parents | |
No parents. | |
Children | |
F-HSR-INJ.1 | No modifications shall be required for present RHIC injector chain. |
F-HSR-INJ.2 | The HSR injection system, consisting of the transport beamline, septum magnet and injection kickers, shall be capable of transporting a maximum beam rigity of 81.12Tm from the transport line to IR4 central area and injecting it into the HSR. |
F-HSR-INJ.3 | The HSR Injection System design shall use a warm transport line in arc 6-4 as continuation of the Injection line to transport the hadron beam to the injection system located in IR4. |
F-HSR-INJ.4 | The HSR injection transport beamline shall be able to transport polarized beam with less than TBD% polarization loss. |
F-HSR-INJ.5 | The HSR injection system shall be able to inject all beam species with less than 5% beam emittance increase. |
F-HSR-INJ.6 | The HSR injection system shall be able to fill the HSR with 290 consecutive bunches without interruption. |
F-HSR-INJ.7 | The HSR injection system shall be able to fill the HSR with one(1) bunch per AGS cycle for polarized proton, two(2) bunches per AGS cycle for ion beams. |
F-HSR-INJ.9 | The operational availability design target for the HSR Injection System shall be consistent with the operational availability target for the overall EIC as set forth in [Electron-Ion Collider Global Requirements, EIC-ORG-PLN-010. |
F-HSR-INJ.8 | The HSR injection system transfer line shall provide a physical aperture of > 6σ for the injector beam. |
F-HSR-INJ.10 | The HSR injection line shall provide at least 6*sigma half aperture in both planes for the injected beam up to the septum. |
This function not yet implemented.