Record Date: 04/22/2025 17:17 | |||
Identifier: | P-HSR-RF-ACAV:24.05.09 | WBS: | 6.08.05.04 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Reviewed | |
Description: | The NCRF Cavity System loop HOM Damper maximum fundamental power leakage under nominal frequency and voltage shall be 200 W. | ||
Comments: |
Record Date: 04/21/2025 19:05 | |||
Identifier: | P-HSR-RF-ACAV:24.05.09 | WBS: | 6.08.05.04 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The NCRF Cavity System e-probe HOM Damper maximum total power on each shall be 0.1 kW. | ||