| Record Date: 07/06/2026 02:38 | |||
| Identifier: | F-HSR-MPS-COLL.09 | WBS: | TBD |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Reviewed | |
| Description: | Collimator jaws shall be independently movable, remotely controllable, and interlocked with beam mode through permit-to-move logic. | ||
| Comments: | |||
No archive versions
| Parents | |
| G-HSR.24 | All HSR collimators shall be double-sided (two-jaw design) with tapered geometry to minimize impedance and wakefield effects. |
| Children | |
| P-HSR-MPS-COLL.10 | Betatron collimator jaws shall provide a motion range sufficient to span from a fully retracted configuration, compatible with machine commissioning without collimation, to operational positions intercepting beam halo at amplitudes on the order of 5σ or below. |
| P-HSR-MPS-COLL.12 | Collimator jaw positioning shall provide a maximum resolution accuracy tolerance of 1um. |
| P-HSR-MPS-COLL.11 | The HSR collimation system collimator jaws shall be independently movable over a range of at minimum 30mm. |
| P-HSR-MPS-COLL.13 | Collimator jaw positioning shall provide reproducibility of 10um or less to support precise collimator alignment, maintain symmetry with respect to the beam axis, and enable fine control of loss distribution downstream. |