| Record Date: 05/14/2026 12:16 | |||
| Identifier: | P-HSR-MAG-Q4-TV:CRC.08.02 | WBS: | 6.02.03.10 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be delivered with three redundant (3x2) Magnet-Quench detection voltage taps located on each magnet lead and at the Magnet-Electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical Magnet-Quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
No archive versions
| Parents | |
| No parents. | |
| Children | |
| No children. |