| Record Date: 08/15/2025 00:29 | |||
| Identifier: | P-HSR-MAG-CQ7(SkewQuad).08.02 | WBS: | 6.05.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be delivered with three redundant (3x2) Magnet-Quench detection voltage taps located on each magnet lead and at the Magnet-Electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical Magnet-Quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-HSR-MAG-CQ7(SkewQuad).08.02 | WBS: | 6.05.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-HSR-MAG-CQ7(SkewQuad).08.02 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Record Date: 02/19/2025 17:21 | |||
| Identifier: | P-HSR-MAG-CQ7(SkewQuad).08.02 | WBS: | 6.05.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be delivered with three redundant (3x2) quench detection voltage taps located on each magnet lead and at the electrical midpoint of the magnet circuit; and two (2) voltage taps for each internal splice. Each voltage tap used for critical quench detection shall have a redundant voltage tap. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |