| Record Date: 08/15/2025 00:29 | |||
| Identifier: | P-HSR-MAG-CQ6(Q6T).07 | WBS: | 6.05.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall have an appropriate Magnet-Quench protection system which ensures all electromagnetic, thermal and cryogenic connected systems are not damaged in a Magnet-Quench event and meets the following constraints: | ||
| Comments: | |||
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-HSR-MAG-CQ6(Q6T).07 | WBS: | 6.05.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall have an appropriate quench protection system which ensures all electromagnetic, thermal and cryogenic connected systems are not damaged in a quench event and meets the following constraints: | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-HSR-MAG-CQ6(Q6T).07 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The magnet shall have an appropriate quench protection system which ensures all electromagnetic, thermal and cryogenic connected systems are not damaged in a quench event and meets the following constraints: | ||
| Comments: | |||
| Record Date: 02/19/2025 17:21 | |||
| Identifier: | P-HSR-MAG-CQ6(Q6T).07 | WBS: | 6.05.02.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall have an appropriate quench protection system which ensures all electromagnetic, thermal and cryogenic connected systems are not damaged in a quench event and meets the following constraints: | ||
| Comments: | |||