Requirement Details
Electron Ion Collider

P-HSR-INJ-PPD-MAG-INDSPTM.08.01
Requirement details, history, relationships and interfaces associated with requirement P-HSR-INJ-PPD-MAG-INDSPTM.08.01
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 09/21/2026 12:32 | |||
| Identifier: | P-HSR-INJ-PPD-MAG-INDSPTM.08.01 | WBS: | 6.02.03.11.02.01.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The induction septum field center displacement (measured with respect to the physical magnet center) shall be X=±150 (µm), Y=±150 (µm), Z=±150 (µm). | ||
| Comments: | |||
| Record Date: 04/08/2026 07:43 | |||
| Identifier: | P-HSR-INJ-PPD-MAG-INDSPTM.08.01 | WBS: | 6.02.03.11.02.01.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | Field center displacement (wrt the physical magnet center) Displacement in X= +/-150 (um) Displacement in Y= +/-150 (um) Displacement in Z= +/-150 (um) | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |