Parents |
No parents. |
Children |
F-ESR-CONT.01 | The ESR control system shall facilitate all ESR global control requirements. |
F-ESR-CONT.02 | The ESR control system shall facilitate all network, relational database and data archiving required. |
F-ESR-CONT.03 | The control system shall facilitate all machine protection systems required |
F-ESR-CONT.04 | The ESR control system shall facilitate all EIC machine timing required. |
F-ESR-CONT.05 | The ESR control system shall facilitate fast orbit feedback integration systems as required. |
F-ESR-CONT.06 | The ESR control system shall facilitate all physics application support required. |
F-ESR-INST.01 | The ESR instrumentation system shall include dual-plane Beam Position Monitors (BPMs) adjacent to each vertically focusing quadrupole. Provisions shall be made in the vacuum chamber design to install additional dual-plane BPMs at the horizontally focusing quadrupoles, if needed. |
F-ESR-INST.02 | The ESR BPMs shall have turn-by-turn orbit measurement capability based on a single, remotely selectable bunch out of the fully filled bunch train to enable injection optimization. |
F-ESR-INST.03 | The ESR instrumentation system shall include a beam current monitor to measure average beam current. |
F-ESR-INST.04 | The ESR instrumentation system shall include a system to measure individual bunch charges and bunch pattern. |
F-ESR-INST.05 | The ESR instrumentation system shall include a system to measure transverse beam profiles. |
F-ESR-INST.06 | The ESR instrumentation system shall include a system to measure longitudinal beam profiles. |
F-ESR-INST.07 | The ESR longitudinal bunch profile monitor needs turn-by-turn capability based on a single bunch in the fully filled bunch train to allow timing and energy adjustment for injection optimization. |
F-ESR-INST.08 | The ESR instrumentation system shall include system to measure H & V betatron tunes. |
F-ESR-INST.09 | The ESR instrumentation system shall facilitate all required feedback systems (slow transverse, longitudinal and transverse bunch-by-bunch) |
F-ESR-RF.06.02 | The ESR RF Systems within the tunnel shall operate within its yearly radiation exposure budget. |
F-ESR-INST.10 | The ESR instrumentation system shall include beam loss monitor system with detectors located only at select regions of the ESR. |
F-ESR-RF.06.05 | The ESR RF System shall be designed to minimize unscheduled downtime, maintenance time and repair time to achieve ESR operational availability. |