Requirement Details
Electron Ion Collider

P-ESR-VAC.06
Requirement details, history, relationships and interfaces associated with requirement P-ESR-VAC.06
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-ESR-VAC.06 | WBS: | 6.04.05 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The average vacuum level in the ESR Arc sections after conditioning (for 1000Ahrs) shall be <5x10-9 Torr. | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-ESR-VAC.06 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The average vacuum level in the ESR Arc sections after conditioning (for 1000Ahrs) shall be <5x10-9 Torr. | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-ESR-VAC.06 | WBS: | 6.04.05 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The average vacuum level in the ESR Arc sections after conditioning (for 1000Ahrs) shall be <5x10-9 Torr. | ||
| Comments: | |||
| Parents | |
| F-ESR-VAC.02 | The dynamic pressure around the ESR shall be consistent with a beam gas lifetime of >10[hrs] with the design currents after an integrated beam current of 1000 [A.h]. |
| Children | |