Record Date: 03/19/2025 17:11 | |||
Identifier: | F-ESR-VAC.01 | WBS: | 6.04.05 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The ESR vacuum chamber shall provide sufficient horizontal and vertical aperture to accommodate; a +/-15 sigma beam, where the vertical RMS beam size is based on the emittance of a fully coupled beam, plus an additional 10 mm horizontal and 5 mm vertical margin to account for expected orbit errors. | ||
Comments: |
Record Date: 02/24/2025 18:26 | |||
Identifier: | F-ESR-VAC.1 | WBS: | 6.04.05 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The ESR vacuum chamber shall provide sufficient horizontal and vertical aperture to accommodate; a +/-15 sigma beam, where the vertical RMS beam size is based on the emittance of a fully coupled beam, plus an additional 10 mm horizontally and 5 mm vertically margin to account for expected orbit errors. | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | F-ESR-VAC.1 | WBS: | 6.04.05 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The vacuum chamber shall provide sufficient horizontal and vertical aperture to accommodate; a +/-15 sigma beam, where the vertical RMS beam size is based on the emittance of a fully coupled beam, plus an additional 10 mm horizontally and 5 mm vertically margin to account for expected orbit errors. | ||
Comments: |
Parents | |
G-ESR.02 | The ESR shall have a depolarization time long enough to ensure an average polarization of 70%, assuming an injected polarization level of 80% and a bunch replacement rate of two bunches per second. |
G-ESR.03 | The ESR shall provide electron bunches having the bunch parameters specified in the MPT. [Document#:EIC-SEG-RSI-005] |
Children | |
P-ESR-VAC.02 | The typical (standard) vacuum chamber aperture shall be 80 x 36 mm. |
P-ESR-VAC.03 | Special aperture requirements and/or aperture file shall be provided by or approved by physics. |
This function not yet implemented.