Requirement Details
Electron Ion Collider
F-ESR-RF.04.01
Requirement details, history, relationships and interfaces associated with requirement F-ESR-RF.04.01
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 05/16/2025 17:04 | |||
Identifier: | F-ESR-RF.04.01 | WBS: | 6.08 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The ESR RF Systems shall achieve an independent beam line vacuum level equivalent to the ESR operational vacuum level. | ||
Comments: |
Record Date: 05/15/2025 20:34 | |||
Identifier: | F-ESR-RF.04.01 | WBS: | |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | ||
Description: | The ESR RF Systems shall achieve an independent beam line vacuum level equivalent to the ESR operational vacuum level. | ||
Comments: |
Record Date: 03/13/2025 17:22 | |||
Identifier: | F-ESR-RF.04.01 | WBS: | 6.08 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The ESR RF Systems shall achieve an independent beam line vacuum level equivalent to the ESR operational vacuum level. | ||
Comments: |
Parents | |
No parents. | |
Children | |
P-ESR-RF-ACAV:591S.01.01 | The SRF Cryomodule shall be outfitted with flow control, thermometry, pressure, and RF instrumentation as to monitor and control all sub-systems during the cooldown, warm-up, operation and testing. |
P-ESR-RF-ACAV:591S.07.02 | The cold beamline maximum vacuum shall be 1.0e-9 mbar. |
P-ESR-RF-ACAV:591S.07.01 | The warm beamline maximum vacuum shall be 5.0e-7 mbar. |
P-ESR-RF-ACAV:591S.07.03 | The beamline vacuum maximum leak rate shall be 5e-10 mbar L/s. |
This function not yet implemented.