| Record Date: 05/16/2025 17:04 | |||
| Identifier: | F-ESR-RF.03.04 | WBS: | 6.08 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The ESR RF Systems shall have alignment verification designed into the system. | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | F-ESR-RF.03.04 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The ESR RF Systems shall have alignment verification designed into the system. | ||
| Comments: | |||
| Record Date: 03/13/2025 17:22 | |||
| Identifier: | F-ESR-RF.03.04 | WBS: | 6.08 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The ESR RF Systems shall have alignment verification designed into the system. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| P-ESR-RF-ACAV:591S.10.05 | The SRF Cryomodule Cavity Electromagnetic Center Alignment Tolerance in X shall be ± 250 μm. |
| P-ESR-RF-ACAV:591S.10.06 | The SRF Cryomodule Cavity Electromagnetic Center Alignment Tolerance in Y shall be ± 250 μm. |
| P-ESR-RF-ACAV:591S.10.07 | The SRF Cryomodule Cavity Electromagnetic Center Alignment Tolerance in Z shall be ± 5 mm. |
| P-ESR-RF-ACAV:591S.10.09 | The SRF Cryomodule Cavity Electromagnetic Center Alignment Tolerance for the pitch shall be ± 0.01 radians. |
| P-ESR-RF-ACAV:591S.10.08 | The SRF Cryomodule Cavity Electromagnetic Center Alignment Tolerance for the roll shall be ± 0.04 radians. |
| P-ESR-RF-ACAV:591S.10.10 | The SRF Cryomodule Cavity Electromagnetic Center Alignment Tolerance for the yaw shall be ± 0.01 radians. |