| Record Date: 05/16/2025 17:04 | |||
| Identifier: | F-ESR-RF.01.02 | WBS: | 6.08 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The ESR RF System shall utilize superconductivity. | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | F-ESR-RF.01.02 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The ESR RF System shall utilize superconductivity. | ||
| Comments: | |||
| Record Date: 03/13/2025 17:22 | |||
| Identifier: | F-ESR-RF.01.02 | WBS: | 6.08 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The ESR RF System shall utilize superconductivity. | ||
| Comments: | |||
| Parents | |
| G-ESR.03 | The ESR shall provide electron bunches having the bunch parameters specified in the MPT. [Document#:EIC-SEG-RSI-005] |
| Children | |
| P-ESR-RF-ACAV:591S.02.01 | The cavity helium bath maximum designed operational temperature shall be 2 K. |
| P-ESR-RF-ACAV:591S.02.02 | The cavity helium bath maximum designed operational pressure shall be 30 mbar. |
| P-ESR-RF-ACAV:591S.02.03 | The cavity helium bath designed operational pressure stability shall be ±0.1 mbar. |
| P-ESR-RF-ACAV:591S.02.04 | The SRF Cryomodule cavity helium jacket shall have a minimum helium bath vapor surface area of 0.049 m^2. |
| P-ESR-RF-ACAV:591S.02.05 | The maximum designed helium supply operational temperature shall be 5.5 K. |
| P-ESR-RF-ACAV:591S.02.06 | The range of the designed helium supply operational pressure shall be 3 to 3.5 bar. |
| P-ESR-RF-ACAV:591S.02.07 | The range of the designed combined helium return temperature shall be 20 to 100 K. |
| P-ESR-RF-ACAV:591S.02.08 | The range of the designed combined helium return pressure shall be 2.4 to 2.6 bar. |
| P-ESR-RF-ACAV:591S.02.09 | The maximum designed sub-atmospheric helium return temperature shall be 4.5 K. |
| P-ESR-RF-ACAV:591S.02.10 | The maximum designed sub-atmospheric helium return pressure shall be 30 mbar. |
| P-ESR-RF-ACAV:591S.06.07 | The SRF cavity maximum Niobium temperature shall be 5 K during operation. |
| P-ESR-RF-ACAV:591S.07.01 | The warm beamline maximum vacuum shall be 5.0e-7 mbar. |
| P-ESR-RF-ACAV:591S.07.02 | The cold beamline maximum vacuum shall be 1.0e-9 mbar. |
| P-ESR-RF-ACAV:591S.07.03 | The beamline vacuum maximum leak rate shall be 5e-10 mbar L/s. |