| Record Date: 12/06/2024 11:10 | |||
| Identifier: | P-ESR-RF-MAIN_RF_SRFCM-FUNDAMENTAL_MODE.14 | WBS: | 6.08.03.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The Microphonics (cold) shall be <500 Hz | ||
| Comments: | |||
No archive versions
| Parents | |
| F-ESR-RF.4 | The RF system shall provide sufficient voltage to provide a bucket height of at least 10 times the rms energy spread of the beam. |
| F-ESR-RF.6 | The superconducting RF system shall allow storage of electron bunches in a 1260 bunch pattern; 1160 buckets will actually be filled with beam while the remaining empty 100 buckets serve as the ion clearing and beam abort gap |
| F-ESR-RF.5 | The RF system shall provide sufficient gradient to allow installation of all necessary cavaties in the allocated beamline space in IR 10. |
| F-ESR-RF.7 | The RF system resonant frequency of the cavities shall be chosen to accommodate the bunch patterns, subject to coordination with the hadron ring. |
| Children | |
| No children. | |