Record Date: 12/06/2024 11:10 | |||
Identifier: | P-ESR-RF-MAIN_RF-FUNDAMENTAL_MODE.27 | WBS: | 6.08.03.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The EM Center Alignment Tolerance Pitch shall be TBD deg | ||
Comments: |
No archive versions
Parents | |
F-ESR-RF.1 | Provision shall be made at IR10 to accommodate RF systems. |
F-ESR-RF.2 | The RF system shall be capable of restoring a maximum synchrotron radiation power loss of 10 MW to the beam. |
F-ESR-RF.3 | The total RF power provided by the RF amplifiers shall be chosen such that all power losses due to synchrotron radiation and other losses created by the stored electron beam can be compensated. |
F-ESR-RF.4 | The RF system shall provide sufficient voltage to provide a bucket height of at least 10 times the rms energy spread of the beam. |
F-ESR-RF.5 | The RF system shall provide sufficient gradient to allow installation of all necessary cavaties in the allocated beamline space in IR 10. |
F-ESR-RF.6 | The superconducting RF system shall allow storage of electron bunches in a 1260 bunch pattern; 1160 buckets will actually be filled with beam while the remaining empty 100 buckets serve as the ion clearing and beam abort gap |
F-ESR-RF.8 | The RF system controls shall be designed to handle the transient beam loading for all necessary bunch patterns. |
F-ESR-RF.7 | The RF system resonant frequency of the cavities shall be chosen to accommodate the bunch patterns, subject to coordination with the hadron ring. |
F-ESR-RF.9 | The HSR Ring RF system shall provide controls and diagnostics for all cavity and system functionality. |
Children | |
No children. |