| Description: | The SRF Cryomodule shall be outfitted with flow control, thermometry, pressure, and RF instrumentation as to monitor and control all sub-systems during the cooldown, warm-up, operation and testing. | ||
| Comments: | |||
No archive versions
| Parents | |
| F-ESR-RF.04.01 | The ESR RF Systems shall achieve an independent beam line vacuum level equivalent to the ESR operational vacuum level. |
| F-ESR-RF.05.01 | The ESR RF Systems shall provide all necessary controls and diagnostics necessary for system operation but not extending beyond the RF System interfaces. |
| F-ESR-RF.05.03 | The ESR RF Systems shall provide 0.02 degree phase stability |
| F-ESR-RF.05.02 | The ESR RF Systems shall provide 0.1% field amplitude stability |
| F-ESR-RF.06.05 | The ESR RF System shall be designed to minimize unscheduled downtime, maintenance time and repair time to achieve ESR operational availability. |
| F-ESR-RF.07.02 | The ESR Storage RF System design shall protect against common electron beam instabilities. |
| F-ESR-RF.07.04 | The ESR Storage RF System shall maintain constant electron beam energy after injection. |
| F-ESR-RF.07.06 | The ESR Storage RF System shall maintain beam energy from 5 to 18 GeV. |