Requirement Details
Electron Ion Collider
F-ESR-MPS-GENERAL.05
Requirement details, history, relationships and interfaces associated with requirement F-ESR-MPS-GENERAL.05
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 10/01/2025 01:20 | |||
Identifier: | F-ESR-MPS-GENERAL.05 | WBS: | 6.06.09.03.01 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Reviewed | |
Description: | The ESR electronic triggers shall be synchronized with the beam abort gap in the ESR bunch train such that the rising edge of the fast abort kicker pulse falls into the abort gap and all ESR bunches receive a sufficiently large kick to detect them safely past the extraction septum and into the fast beam dump. | ||
Comments: |
No archive versions
Parents | |
No parents. | |
Children | |
No children. |