Requirement Details
Electron Ion Collider

P-ESR-MAG-QSS1.10
Requirement details, history, relationships and interfaces associated with requirement P-ESR-MAG-QSS1.10
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-ESR-MAG-QSS1.10 | WBS: | 6.04.03.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be designed to operate reliably given the cumulative radiation dose it will experience over the lifetime of the EIC of >20 Years. | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-ESR-MAG-QSS1.10 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The magnet shall be designed to operate reliably given the cumulative radiation dose it will experience over the lifetime of the EIC of >20 Years. | ||
| Comments: | |||
| Record Date: 02/05/2025 16:53 | |||
| Identifier: | P-ESR-MAG-QSS1.10 | WBS: | 6.04.03.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be designed to operate reliably given the cumulative radiation dose it will experience over the lifetime of the EIC of >20 Years. | ||
| Comments: | |||
| Record Date: 02/04/2025 17:22 | |||
| Identifier: | P-ESR-MAG-QSS1.10 | WBS: | 6.06.02.01.03.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be designed to operate reliably given the cumulative radiation dose it will experience over the lifetime of the EIC of >20 Years. | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-ESR-MAG-QSS1.10 | WBS: | 6.06.02.01.03.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet good field aperture dAx required shall be 31.4421 mm. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |
This function not yet implemented.