Requirement Details
Electron Ion Collider
P-ESR-MAG-CORR_V.20
Requirement details, history, relationships and interfaces associated with requirement P-ESR-MAG-CORR_V.20
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 10/10/2024 14:48 | |||
Identifier: | P-ESR-MAG-CORR_V.20 | WBS: | 6.04.03.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The Field at the reference radius at the design energy of 18 GeV shall be 60e-3 (T) . | ||
Comments: |
No archive versions
Parents | |
F-ESR-CONT.1 | The ESR control system shall facilitate all ESR global control requirements.  |
F-ESR-MAG.1 | The magnets shall meet the requirements defined by the physics lattice. |
F-ESR-MAG.2 | The magnets shall have the required field quality to meet the operational needs. |
F-ESR.1 | The ESR lattice shall provide a minimum dynamic aperture of 10 sigma w.r.t Gaussian electron beam distribution in all three dimensions, horizontal, vertical, and longitudinal. With the vertical emittance being half the horizontal design emittance. |
F-ESR.2 | The minimum dynamic aperture shall be achieved in two optics configurations (60 and 90 degrees betatron phase advance per FODO cell) at all operational beam energies as per [5.9], and with one and with two low-beta insertions. |
F-ESR.3 | The ESR shall support two low-beta insertions (colliding beam interaction regions) at IRs 6 and 8. |
F-ESR.4 | The ESR alignment requirements are established by dynamic aperture and polarization tracking. The ESR RMS alignment tolerances shall be such that all the beam parameter listed in [5.9] can be satisfied. |
F-ESR.5 | The ESR shall reach an availability consistent with the overall availability of the entire EIC as specified in [5.9]. |
F-IR.9 | The IR shall be designed so that the electron and hadron beams have the same cross-sectional area and maximum overlap to achieve the high luminosities required in [5.8]. |
F-IR.8 | The IR shall be designed to ensure the hadron and electron beam collisions at the IP meet all the performance requirements set forth in [5.8]. |
F-IR.11 | The IR operational uptime shall match the operational uptime requirements of the EIC. |
Children | |
No children. |