| Record Date: 02/06/2025 16:54 | |||
| Identifier: | P-ESR-MAG-CORR_V.03 | WBS: | 6.04.03.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The magnet shall be measured using the field homogeneity measurement methodology defined to satisfy its operational harmonic multipole content constraints. | ||
| Comments: | |||
| Record Date: 02/05/2025 16:53 | |||
| Identifier: | P-ESR-MAG-CORR_V.03 | WBS: | 6.04.03.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet shall be measured using the field homogeneity measurement methodology defined to satisfy its operational harmonic multipole content constraints. | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-ESR-MAG-CORR_V.3 | WBS: | 6.04.03.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The magnet shall not require current taps for operation. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |