Record Date: 05/16/2025 17:04 | |||
Identifier: | F-ESR-INST.10 | WBS: | 6.04.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The ESR instrumentation system shall include beam loss monitor system with detectors located only at select regions of the ESR. | ||
Comments: |
Record Date: 05/15/2025 20:34 | |||
Identifier: | F-ESR-INST.10 | WBS: | |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | ||
Description: | The ESR instrumentation system shall include beam loss monitor system with detectors located only at select regions of the ESR. | ||
Comments: |
Record Date: 02/24/2025 18:26 | |||
Identifier: | F-ESR-INST.10 | WBS: | 6.04.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The ESR instrumentation system shall include beam loss monitor system with detectors located only at select regions of the ESR. | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | F-ESR-INST.10 | WBS: | 6.04.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Reviewed | |
Description: | The instrumentation system shall include beam loss monitor system with detectors located only at select regions of the ESR. | ||
Comments: |
Parents | |
G-ESR.03 | The ESR shall provide electron bunches having the bunch parameters specified in the MPT. [Document#:EIC-SEG-RSI-005] |
G-ESR.17 | The ESR shall have provisions made to accommodate a control system which can operate the ESR consistent will the overall control of the EIC and other EIC systems and to ensure the ESR meets all the Physics requirements needed to deliver the physics goals of the EIC. |
Children | |
P-ESR-INST-BLM.01 | BLM shall be needed to needed to protect sensitive equipment. |
P-ESR-INST-BLM.02 | The number of BLM installed in the ESR shall be TBD ea |
P-ESR-INST-BLM.03 | BLM shall be installed at the following locations in the ESR TBD |
P-ESR-INST-BLM.04 | The sensitivity of the BLM detectors shall be TBD units? |
P-ESR-INST-BLM.05 | Where possible existing RHIC BLM's can be relocated to identify ESR & HSR losses |
P-ESR-INST-BLM.06 | The response time from loss detection to abort shall be TBD us |