Requirement Details
Electron Ion Collider
F-ESR-INST.3
Requirement details, history, relationships and interfaces associated with requirement F-ESR-INST.3
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 10/10/2024 14:48 | |||
Identifier: | F-ESR-INST.3 | WBS: | 6.04 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The instrumentation system shall include a beam current monitor to measure average beam current | ||
Comments: |
No archive versions
Parents | |
G-ESR.3 | The ESR shall provide electron bunches having the bunch parameters specified in [10]Â |
G-ESR.15 | The ESR shall have a control system which can operate the ESR consistent will the overall control of the other EIC system's and to ensure the ESR meets all the Physics requirements needed to deliver the physics goals of the EIC. |
Children | |
P-ESR-INST-DCCT.1 | A DCCT shall measure the average beam current in the ESR. |
P-ESR-INST-DCCT.2 | The measurement resolution averaged over 1 sec shall be < 5 uA |
P-ESR-INST-DCCT.3 | The DCCT beamline device impedance shall be approved by beam physics. |
P-ESR-INST-DCCT.4 | Measurement drift tolerance (thermal effects) shall be ≤ 1 uA/K |
P-ESR-INST-DCCT.5 | The DCCT sensor in the ring shall operate in the temperature range of 15 to 35 degrees C |
P-ESR-INST-DCCT.6 | The range of average beam current to be measured shall be 0.156x10-3 to 2.5 A |
P-ESR-INST-DCCT.7 | The DCCT system shall have a remote controlled self calibration system |
P-ESR-INST-DCCT.8 | The DCCT system shall provide measurements with absolute accuracy of better than 0.2 % |
P-ESR-INST-DCCT.9 | The measured average current shall be provided to users at a rate of 10 Hz |
P-ESR-INST-DCCT.10 | The measured average current shall be archived at a rate of 10 Hz Hz |
P-ESR-INST-DCCT.11 | The DCCT sensor assembly in the ring shall be radiation resistant |
This function not yet implemented.