Requirement Details
Electron Ion Collider

P-ESR-INST-DCCT.05
Requirement details, history, relationships and interfaces associated with requirement P-ESR-INST-DCCT.05
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 10/03/2025 04:06 | |||
| Identifier: | P-ESR-INST-DCCT.05 | WBS: | 6.04.06.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The ESR DC Current Transformer system average beam current measurement shall have an absolute accuracy between the range of 250 (mA) to 2.5 (A) at +/- 0.5 (%). | ||
| Comments: | |||
| Record Date: 09/30/2025 00:36 | |||
| Identifier: | P-ESR-INST-DCCT.05 | WBS: | 6.04.06.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The DC Current Transformer shall have the ability to measure the average beam current over a range of 0.15 (mA) to 2500 (mA). | ||
| Comments: | |||
| Record Date: 09/22/2025 23:07 | |||
| Identifier: | P-ESR-INST-DCCT.05 | WBS: | 6.04.06.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The DC Current Transformer shall have the ability to measure the average beam current over a range of 0.156 to 2500 mA | ||
| Comments: | |||
| Record Date: 09/16/2025 00:57 | |||
| Identifier: | P-ESR-INST-DCCT.05 | WBS: | 6.04.06.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The ESR DC Current Transformer shall have the ability to measure the average beam current over a range of 0.156 to 2500 mA | ||
| Comments: | |||
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-ESR-INST-DCCT.05 | WBS: | 6.04.06.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The DCCT sensor in the ring shall operate in the temperature range of 15 to 35 degrees C | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-ESR-INST-DCCT.05 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The DCCT sensor in the ring shall operate in the temperature range of 15 to 35 degrees C | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-ESR-INST-DCCT.05 | WBS: | 6.04.06.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The DCCT sensor in the ring shall operate in the temperature range of 15 to 35 degrees C | ||
| Comments: | |||
| Parents | |
| F-EIS-INST.1 | EIS shall have all the beam instrumentation necessary to deliver the operational parameters set forth in the MPT. [Document#:EIC-SEG-RSI-005] |
| F-ESR-INST.03 | The ESR instrumentation system shall include a beam current monitor to measure average beam current. |
| Children | |
| No children. | |