Requirement Details
Electron Ion Collider

P-ESR-INST-BPM-PU.09
Requirement details, history, relationships and interfaces associated with requirement P-ESR-INST-BPM-PU.09
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 02/09/2026 20:55 | |||
| Identifier: | P-ESR-INST-BPM-PU.09 | WBS: | 6.02.02.05.01.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The mechanical center of the ESR Beam Position Monitor Pickups, i.e., the horizontal and vertical position alignment tolerances with respect to its fiducials shall be known to a certainty within +/- 200 (um). | ||
| Comments: | |||
| Record Date: 10/16/2025 00:47 | |||
| Identifier: | P-ESR-INST-BPM-PU.09 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The mechanical center of the ESR Beam Position Monitor Pickups, i.e., the horizontal and vertical position alignment tolerances with respect to its fiducials shall be known to a certainty within +/- 200 (um). | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |