Requirement Details
Electron Ion Collider

P-ESR-INST-BPM-PU.08.01
Requirement details, history, relationships and interfaces associated with requirement P-ESR-INST-BPM-PU.08.01
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 02/09/2026 20:55 | |||
| Identifier: | P-ESR-INST-BPM-PU.08.01 | WBS: | 6.02.02.05.01.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The scaling accuracy of the ESR BPMs shall be ≤ +/- 100 (μm) in the +/-3 (mm) measurement range defined for fill (FILL), luminosity (LUMI), and Beam Based Alignment (BBA) operations. | ||
| Comments: | |||
| Record Date: 10/16/2025 00:47 | |||
| Identifier: | P-ESR-INST-BPM-PU.08.01 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The scaling accuracy of the ESR BPMs shall be ≤ +/- 100 (μm) in the +/-3 (mm) measurement range defined for fill (FILL), luminosity (LUMI), and Beam Based Alignment (BBA) operations. | ||
| Comments: | |||
| Record Date: 10/13/2025 08:07 | |||
| Identifier: | P-ESR-INST-BPM-PU.08.01 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Not Applicable | |
| Description: | The offset precision (long term, second time scales) of the ESR BPMs shall be ≤ +/-1 (μm) in Closed Orbit (CO) mode in ESR luminosity (LUMI) operation with a time window of 1 s. | ||
| Comments: | |||
| Record Date: 10/08/2025 12:43 | |||
| Identifier: | P-ESR-INST-BPM-PU.08.01 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Reviewed | |
| Description: | The offset precision (long term, second time scales) of the ESR BPMs shall be ≤ +/-1 (μm) in Closed Orbit (CO) mode in ESR luminosity (LUMI) operation with a time window of 1 s. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |