| Record Date: 02/09/2026 20:55 | |||
| Identifier: | P-ESR-INST-BPM-PU.06.04 | WBS: | 6.02.02.05.01.02 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The ESR resolution, RMS, short term (ns, µs time scales) of the ESR BPMs shall be ≤ 5 (μm) for position measurements in Closed Orbit (CO) mode in ESR luminosity (LUMI) operation. | ||
| Comments: | |||
| Record Date: 10/16/2025 00:47 | |||
| Identifier: | P-ESR-INST-BPM-PU.06.04 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The ESR resolution, RMS, short term (ns, µs time scales) of the ESR BPMs shall be ≤ 5 (μm) for position measurements in Closed Orbit (CO) mode in ESR luminosity (LUMI) operation. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |