Requirement Details
Electron Ion Collider

P-ESR-INST-BPM-PU.06.02
Requirement details, history, relationships and interfaces associated with requirement P-ESR-INST-BPM-PU.06.02
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 10/16/2025 00:47 | |||
| Identifier: | P-ESR-INST-BPM-PU.06.02 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The resolution, RMS, short term (ns, µs time scales) of the first 20 ESR BPMs after injection shall be ≤ 15 (μm) for position measurements in single-bunch / bunch-by-bunch (BbB) during ESR luminosity (LUMI) operation. | ||
| Comments: | |||
| Record Date: 10/13/2025 08:07 | |||
| Identifier: | P-ESR-INST-BPM-PU.06.02 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Not Applicable | |
| Description: | The ESR BPMs shall have +/- 10 (mm) horizontal and vertical beam position range in the 80 (mm) ×36 (mm) chamber for position measurements in machine commissioning (COMM) operations. | ||
| Comments: | |||
| Record Date: 10/08/2025 12:43 | |||
| Identifier: | P-ESR-INST-BPM-PU.06.02 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Reviewed | |
| Description: | The ESR BPMs shall have +/- 10 (mm) horizontal and vertical beam position range in the 80 (mm) ×36 (mm) chamber for position measurements in machine commissioning (COMM) operations. | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |