| Record Date: 10/16/2025 00:47 | |||
| Identifier: | P-ESR-INST-BPM-PU.05 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Approved | |
| Description: | The ESR BPM system shall fulfill resolution and accuracy requirements over the following two defined transverse beam position ranges with respect vacuum chamber center, referenced to the mechanical fiducials on the BPM pickups. | ||
| Comments: | |||
| Record Date: 10/13/2025 08:07 | |||
| Identifier: | P-ESR-INST-BPM-PU.05 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Not Applicable | |
| Description: | The ESR BPM system shall fulfill resolution and accuracy requirements over the horizontal and vertical beam position range of approximately +/- 3 (mm) and +/- 10 (mm) with respect vacuum chamber center, referenced to the mechanical fiducials on the BPM pickups. | ||
| Comments: | |||
| Record Date: 10/08/2025 12:43 | |||
| Identifier: | P-ESR-INST-BPM-PU.05 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Reviewed | |
| Description: | The ESR BPM system shall fulfill resolution and accuracy requirements over the horizontal and vertical beam position range of approximately +/- 3 (mm) and +/- 10 (mm) with respect vacuum chamber center, referenced to the mechanical fiducials on the BPM pickups. | ||
| Comments: | |||
| Record Date: 10/03/2025 04:06 | |||
| Identifier: | P-ESR-INST-BPM-PU.05 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Not Applicable | |
| Description: | The ESR Beam Position Monitor Pick-Ups housing shall have a +/- 10 (mrad) corresponding to +/- 0.6 (degree) roll tolerance with regards to BPM measurements in respect to the vacuum chamber. | ||
| Comments: | |||
| Record Date: 09/24/2025 00:45 | |||
| Identifier: | P-ESR-INST-BPM-PU.05 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The ESR Beam Position Monitor Pick-Ups housing shall have a +/- 10 (mrad) corresponding to +/- 0.6 (degree) roll tolerance with regards to BPM measurements in respect to the vacuum chamber. | ||
| Comments: | |||
| Record Date: 07/25/2025 02:58 | |||
| Identifier: | P-ESR-INST-BPM-PU.05 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The ESR Beam Position Monitor Pick-Ups design shall be less than or equal to the allocated impedance and is within the accepted overall ESR impedance budget approved by physics. (replace with loss factor) | ||
| Comments: | |||
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-ESR-INST-BPM-PU.05 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The total number of ESR BPM pick-ups shall be 220 BPMs | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-ESR-INST-BPM-PU.05 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The total number of ESR BPM pick-ups shall be 220 BPMs | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-ESR-INST-BPM-PU.05 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The total number of ESR BPM pick-ups shall be 220 BPMs | ||
| Comments: | |||
| Parents | |
| F-ESR-INST.01 | The ESR instrumentation system shall include dual-plane Beam Position Monitors (BPMs) adjacent to each vertically focusing quadrupole. Provisions shall be made in the vacuum chamber design to install additional dual-plane BPMs at the horizontally focusing quadrupoles, if needed. |
| F-EIS-INST.1 | EIS shall have all the beam instrumentation necessary to deliver the operational parameters set forth in the MPT. [Document#:EIC-SEG-RSI-005] |
| F-ESR-INST.02 | The ESR BPMs shall have turn-by-turn orbit measurement capability based on a single, remotely selectable bunch out of the fully filled bunch train to enable injection optimization. |
| Children | |
| No children. | |
This function not yet implemented.