| Record Date: 10/03/2025 04:06 | |||
| Identifier: | P-ESR-INST-BPM-PU.04 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | Not Applicable | |
| Description: | The ESR Beam Position Monitor Pick-Ups mechanical center change with respect to its fiducials shall be within +/- 20 (um) due to the expected thermal and vacuum variances. | ||
| Comments: | |||
| Record Date: 09/24/2025 00:45 | |||
| Identifier: | P-ESR-INST-BPM-PU.04 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The ESR Beam Position Monitor Pick-Ups mechanical center change with respect to its fiducials shall be within +/- 20 (um) due to the expected thermal and vacuum variances. | ||
| Comments: | |||
| Record Date: 07/25/2025 02:58 | |||
| Identifier: | P-ESR-INST-BPM-PU.04 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | The ESR Beam Position Monitor Pick-Ups housing shall have a +/- 10 (mrad) corresponding to +/- 0.6 (degree) roll tolerance with regards to BPM measurements in respect to the vacuum chamber. | ||
| Comments: | |||
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-ESR-INST-BPM-PU.04 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | Special BPM pick-ups shall be located between the RF cavities in sector 10, for position resolution | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-ESR-INST-BPM-PU.04 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | Special BPM pick-ups shall be located between the RF cavities in sector 10, for position resolution | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-ESR-INST-BPM-PU.04 | WBS: | 6.04.06.01 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | Special BPM pick-ups shall be located between the RF cavities in sector 10, for position resolution | ||
| Comments: | |||
| Parents | |
| No parents. | |
| Children | |
| No children. |