Description: | The control system shall facilitate all machine protection systems required | ||
Comments: |
No archive versions
Parents | |
G-EIS.12 | The EIS shall contain appropirate protection systems to protect the magnine from damage and to minimise machine downtime |
G-EIS.15 | Placeholder Need a high level controls requirement |
Children | |
P-EIS-GUN-CONT.1 | The polarization monitoring rate shall be 8 bunches at 1 Hz |
P-EIS-GUN-CONT.2 | The spin state control command window prior to laser trigger shall be 10 ms |
P-EIS-GUN-CONT.3 | PlaceHolder- Other Gun\source controil requirements? - - |
P-EIS-RCS-CONT.1 | The beam based alignment shall power the quadrapole magnets to +/- .15 k1 |
P-EIS-RCS-CONT.2 | The beam based alignment BPM's shall be placed in the following locations tbd |
P-EIS-RCS-CONT.3 | The orbit display rate shall be 1 Hz |
P-EIS-RCS-CONT.4 | The orbit feed-forward optimization rate shall be 1 Hz |
P-EIS-RCS-CONT.5 | The orbit corrections sampling rate shall be 78 kHz |
P-EIS-RCS-CONT.6 | The tunes feed-forward optimization period shall be 6 hrs +/- 1 |
P-EIS-RCS-CONT.7 | The chromaticity feed-forward optimization rate shall be 6 hrs +/- 1 |
P-EIS-RCS-CONT.8 | The fast context switching available PPM contexts shall be 8 cnt |
P-EIS-RCS-CONT.9 | The fast context switching shall apply to selected RF components in the following locations tbd |
P-EIS-RCS-CONT.10 | The fast context switching shall apply to selected PS components in the following locations tbd |
P-EIS-RCS-CONT.11 | The fast context switching shal apply to selected Inst components in the following locations tbd |
P-EIS-RCS-CONT.12 | The fast context switching shall support manual and automated control in the following locations tbd |
P-EIS-RCS-CONT.13 | The fast context switching min context switching period shall be 1 sec |
This function not yet implemented.