Requirement Details
Electron Ion Collider
F-EIS.12
Requirement details, history, relationships and interfaces associated with requirement F-EIS.12
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 01/27/2025 16:43 | |||
Identifier: | F-EIS.12 | WBS: | 6.07.02 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The EIS control system shall facilitate all network, relational database and data archiving required. | ||
Comments: |
No archive versions
Parents | |
G-EIS.14 | The EIS shall have a control system which can operate the EIS consistent will the overall control of the other EIC system's and to ensure the ESR meets all the Physics requirements needed to deliver the physics goals of the EIC. |
Children | |
P-EIS-GUN-CONT.2 | The spin state control command window prior to laser trigger shall be 10 ms |
P-EIS-GUN-CONT.1 | The polarization monitoring rate shall be 8 bunches at 1 Hz |
P-EIS-GUN-CONT.3 | PlaceHolder- Other Gun\source controil requirements? - - |
P-EIS-RCS-CONT.1 | The beam based alignment shall power the quadrapole magnets to +/- .15 k1 |
P-EIS-RCS-CONT.2 | The beam based alignment BPM's shall be placed in the following locations tbd |
P-EIS-RCS-CONT.3 | The orbit display rate shall be 1 Hz |
P-EIS-RCS-CONT.4 | The orbit feed-forward optimization rate shall be 1 Hz |
P-EIS-RCS-CONT.5 | The orbit corrections sampling rate shall be 78 kHz |
P-EIS-RCS-CONT.6 | The tunes feed-forward optimization period shall be 6 hrs +/- 1 |
P-EIS-RCS-CONT.7 | The chromaticity feed-forward optimization rate shall be 6 hrs +/- 1 |
P-EIS-RCS-CONT.8 | The fast context switching available PPM contexts shall be 8 cnt |
P-EIS-RCS-CONT.9 | The fast context switching shall apply to selected RF components in the following locations tbd |
P-EIS-RCS-CONT.10 | The fast context switching shall apply to selected PS components in the following locations tbd |
P-EIS-RCS-CONT.11 | The fast context switching shal apply to selected Inst components in the following locations tbd |
P-EIS-RCS-CONT.12 | The fast context switching shall support manual and automated control in the following locations tbd |
P-EIS-RCS-CONT.13 | The fast context switching min context switching period shall be 1 sec |
This function not yet implemented.