Requirement Details
Electron Ion Collider

P-EIS-RCS-INST-BPM.13
Requirement details, history, relationships and interfaces associated with requirement P-EIS-RCS-INST-BPM.13
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 10/10/2024 14:48 | |||
| Identifier: | P-EIS-RCS-INST-BPM.13 | WBS: | 6.03.02.05 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | Measurement resolution for single bunch (after merges), single turn, high charge/bunch (7-28 nC) shall be 100 microns | ||
| Comments: | |||
No archive versions
| Parents | |
| F-EIS-RCS-INST-BBA.1 | The RCS shall contain a beam-based alignment system. |
| F-EIS-RCS-INST-BPM.1 | The instrumentation system shall contain a Beam Position Monitor system consisting of dual-plane Beam Position Monitors adjacent to each quadrupole. |
| F-EIS-RCS-INST-BPM.2 | Select Beam Position Monitors in the injection region shall have turn-by-turn orbit measurement capability based on a single, remotely selectable bunch out of the fully filled bunch train to enable injection optimization. |
| F-EIS.8 | EIS shall have all the beam instrumentation necessary to deliver the operational parameters set forth in [5.9]. |
| Children | |
| No children. | |
This function not yet implemented.