Requirement Details
Electron Ion Collider
P-EIS-RCS-INST-BPM-PU.4
Requirement details, history, relationships and interfaces associated with requirement P-EIS-RCS-INST-BPM-PU.4
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 01/27/2025 16:43 | |||
Identifier: | P-EIS-RCS-INST-BPM-PU.4 | WBS: | 6.03.02.05.01 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | BPM pick-ups design shall ensure the simulated impedance is within the accepted overall RCS impedance budget | ||
Comments: |
No archive versions
Parents | |
F-EIS-RCS-INST-BBA.1 | The RCS shall contain a beam-based alignment system. |
F-EIS-RCS-VAC.3 | The impedance of the entire RCS vacuum system shall allow for the bunch intensities, beam currents, and bunch numbers contained in [5.9]. |
F-EIS-RCS-INST-BPM.1 | The instrumentation system shall contain a Beam Position Monitor system consisting of dual-plane Beam Position Monitors adjacent to each quadrupole. |
F-EIS-RCS-INST-BPM.2 | Select Beam Position Monitors in the injection region shall have turn-by-turn orbit measurement capability based on a single, remotely selectable bunch out of the fully filled bunch train to enable injection optimization. |
F-EIS.8 | EIS shall have all the beam instrumentation necessary to deliver the operational parameters set forth in [5.9]. |
Children | |
No children. |