Requirement Details
Electron Ion Collider

F-EIS-PREINJ-GUN.3
Requirement details, history, relationships and interfaces associated with requirement F-EIS-PREINJ-GUN.3
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | F-EIS-PREINJ-GUN.3 | WBS: | 6.03.04 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | When illuminated with a circular polarized laser the pre-injector electron gun shall produce the polarized electrons required to operate the EIC. | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | F-EIS-PREINJ-GUN.3 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | When illuminated with a circular polarized laser the pre-injector electron gun shall produce the polarized electrons required to operate the EIC. | ||
| Comments: | |||
| Record Date: 03/17/2025 17:06 | |||
| Identifier: | F-EIS-PREINJ-GUN.3 | WBS: | 6.03.04 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | In Process | |
| Description: | When illuminated with a circular polarized laser the pre-injector electron gun shall produce the polarized electrons required to operate the EIC. | ||
| Comments: | |||
| Record Date: 03/13/2025 17:22 | |||
| Identifier: | F-EIS-PREINJ-GUN.3 | WBS: | 6.03.04 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | On Hold | |
| Description: | When illuminated with a circular polarized laser the pre-injector electron gun shall produce the polarized electrons required to operate the EIC. | ||
| Comments: | |||
| Parents | |
| G-EIS.1 | The EIS shall provide an electron beam having sufficient polarization as required by the ESR to meet the operational modes set forth in the Master Parameter Table (MPT). [Document#:EIC-SEG-RSI-005] |
| Children | |
| P-EIS-GUN-ESOURCE.01 | The e-Gun system requires a minimum electrical service 300\208 Amps\Vac |
| P-EIS-GUN-ESOURCE.02 | The maximum power consumption required for the Gun systems should not exceed. 108 kVA |
| P-EIS-GUN-ESOURCE.03 | The gun system shall be designed to operate in a Class 100 (ISO 5) clean room with its temperature maintained at 18 +/- 2 °C |
| P-EIS-GUN-ESOURCE.04 | The gun vacuum shall be able to achieve and maintain <10-11 Torr |
| P-EIS-GUN-ESOURCE.05 | The bunch parameters from the cathode for 5&11GeV operation shall have a bunch charge of 7 nC |
| P-EIS-GUN-ESOURCE.06 | The bunch parameters from the cathode for 18GeV operation shall have a bunch charge of 5 nC |
| P-EIS-GUN-ESOURCE.07 | The bunch parameters from the cathode shall have a initial bunch length (FWHM) of 1.6 ns |
| P-EIS-GUN-ESOURCE.08 | The bunch parameters from the cathode shall have a bunch Diameter(hard edge) within the range of 6-10 mm |
| P-EIS-GUN-ESOURCE.09 | The bunch parameters from the cathode shall have a Longitudinal profile distribution which is flat |
| P-EIS-GUN-ESOURCE.10 | The bunch parameters from the cathode shall have a Transverse Gaussian distribution with a σ of 6 to 10 mm |
| P-EIS-GUN-ESOURCE.11 | The bunch parameters from the cathode shall have a Gun voltage in the range of 290 to 350 keV |
| P-EIS-GUN-ESOURCE.12 | The gun shall be capable of generating four bunches with each bunch separated by at least 12.8295593046379 µs |
| P-EIS-GUN-ESOURCE.13 | The gun shall be capable of reproducing the entire 4 bunch pairs with a repetition rate of 1 Hz |
| P-EIS-GUN-ESOURCE.14 | For 7[nC] bunches the average current from the gun shall be 56 nA |
| P-EIS-GUN-ESOURCE.15 | For 5[nC] bunches the average current from the gun shall be 40 nA |
| P-EIS-GUN-ESOURCE.17 | The electron gun design for pre-injector shall permit the exchange of the cathode in Approx 2 hrs |
| P-EIS-GUN-ESOURCE.16 | The gun shall have an operational lifetime of >. 2 Wks |
| P-EIS-GUN-ESOURCE.18 | Minimum e-Beam polarization from gun shall be >85 % |
This function not yet implemented.