Requirement Details
Electron Ion Collider

P-EIS-METL-VAC.06
Requirement details, history, relationships and interfaces associated with requirement P-EIS-METL-VAC.06
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
| Record Date: 05/16/2025 17:04 | |||
| Identifier: | P-EIS-METL-VAC.06 | WBS: | 6.03.03.03 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | On Hold | |
| Description: | The average vacuum level in all EIS medium energy transfer line after conditioning (for 1000hrs) shall be 5x10^-8 Torr | ||
| Comments: | |||
| Record Date: 05/15/2025 20:34 | |||
| Identifier: | P-EIS-METL-VAC.06 | WBS: | |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | ||
| Description: | The average vacuum level in all EIS medium energy transfer line after conditioning (for 1000hrs) shall be 5x10^-8 Torr | ||
| Comments: | |||
| Record Date: 01/27/2025 16:43 | |||
| Identifier: | P-EIS-METL-VAC.06 | WBS: | 6.03.03.03 |
| Date Modified: | TBD: | FALSE | |
| Status Date: | Status: | On Hold | |
| Description: | The average vacuum level in all EIS medium energy transfer line after conditioning (for 1000hrs) shall be 5x10^-8 Torr | ||
| Comments: | |||
| Parents | |
| F-EIS-VAC.1 | The EIS vacuum system shall meet UHV standards at a minimum (Ref vacuum spec?) |
| F-EIS-VAC.2 | The impedance of the entire EIS vacuum system, including the transport lines, shall allow for the bunch intensities, beam currents, and bunch numbers contained in the MPT. [Document#:EIC-SEG-RSI-005] |
| F-EIS-VAC.3 | The size, location and type of vacuum pumps shall be chosen to meet the required vacuum levels during operation |
| F-EIS-VAC.4 | Appropriate vacuum gauging shall be supplied in each vacuum sector to monitor the required vacuum levels |
| Children | |
| No children. | |