Requirement Details
Electron Ion Collider
P-EIS-METL-VAC.06
Requirement details, history, relationships and interfaces associated with requirement P-EIS-METL-VAC.06
CURRENT RECORD
ARCHIVE RECORDS
RELATIONSHIPS
INTERFACES
Record Date: 01/27/2025 16:43 | |||
Identifier: | P-EIS-METL-VAC.06 | WBS: | 6.03.03.03 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | On Hold | |
Description: | The average vacuum level in all EIS medium energy transfer line after conditioning (for 1000hrs) shall be 5x10^-8 Torr | ||
Comments: |
No archive versions
Parents | |
F-EIS-VAC.1 | The EIS vacuum system shall meet UHV standards at a minimum (Ref vacuum spec?) |
F-EIS-VAC.2 | The impedance of the entire EIS vacuum system, including the transport lines, shall allow for the bunch intensities, beam currents, and bunch numbers contained in the MPT. [Document#:EIC-SEG-RSI-005] |
F-EIS-VAC.3 | The size, location and type of vacuum pumps shall be chosen to meet the required vacuum levels during operation |
F-EIS-VAC.4 | Appropriate vacuum gauging shall be supplied in each vacuum sector to monitor the required vacuum levels |
Children | |
No children. |