Requirement Details
Electron Ion Collider
P-EIS-METL-INST-BPM.5
Requirement details, history, relationships and interfaces associated with requirement P-EIS-METL-INST-BPM.5
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 10/10/2024 14:48 | |||
Identifier: | P-EIS-METL-INST-BPM.5 | WBS: | 6.03.03.04 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The BPM pick-up alignment accuracy with respect to to its nearby quadrapole magnet shall be better than 100 µm | ||
Comments: |
No archive versions
Parents | |
F-EIS-METL-INST.1 | To measure and control the beam in the medium energy 400 MeV transfer line there shall be sufficient beam position monitors for orbit control, transverse profile monitors, and bunch charge monitors as required. |
F-EIS.8 | EIS shall have all the beam instrumentation necessary to deliver the operational parameters set forth in [5.9]. |
Children | |
No children. |