Requirement Details
Electron Ion Collider
P-EIS-HETL-VAC.2
Requirement details, history, relationships and interfaces associated with requirement P-EIS-HETL-VAC.2
- CURRENT RECORD
- ARCHIVE RECORDS
- RELATIONSHIPS
- INTERFACES
Record Date: 12/06/2024 11:10 | |||
Identifier: | P-EIS-HETL-VAC.2 | WBS: | 6.03.03.03 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | On Hold | |
Description: | The typical vacuum chamber aperture shall be 32.9 mm | ||
Comments: |
No archive versions
Parents | |
F-EIS.4 | The EIS vacuum system shall meet UHV standards at a minimum (Ref vacuum spec?) |
F-EIS.6 | The size, location and type of vacuum pumps shall be chosen to meet the required vacuum levels during operation |
F-EIS.5 | The impedance of the entire EIS vacuum system, including the transport lines, shall allow for the bunch intensities, beam currents, and bunch numbers contained in [5.9]. |
F-EIS.7 | Appropriate vacuum gauging shall be supplied in each vacuum sector to monitor the required vacuum levels |
Children | |
No children. |
This function not yet implemented.