Record Date: 10/10/2024 14:48 | |||
Identifier: | F-EIS-GUN-INST.5 | WBS: | 6.03 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The Diagnostic beamline section shall have one Beam Profile Monitor and Wien Filter and an electrostatic bender before the Mott polarimeter and Faraday Cup. | ||
Comments: |
No archive versions
Parents | |
G-EIS.2 | The EIS shall provide an electron beam having sufficient energy to meet the ESR beam requirements as set forth in [5.9]. |
G-EIS.3 | The EIS shall provide an electron beam with the RMS bunch momentum spreads at extraction which meet the ESR beam requirements as set forth in [5.9]. |
G-EIS.4 | The EIS pre-injector shall provide an electron beam to the ESR having a horizontal beam emittance which is compatible with operation of the ESR. |
G-EIS.5 | The EIS pre-injector shall provide an electron beam to the ESR having a vertical beam emittance which is compatible with operation of the ESR. |
G-EIS.6 | The EIS shall inject into the ESR at a rate of 1[Hz]. |
G-EIS.7 | The EIS shall inject one bunch into the ESR whilst being able to provide 2 bunches per injection cycle. |
G-EIS.9 | The EIS shall provide an electron beam to the ESR having the bunch charge at extraction to meet the beam requirements as set forth in [5.9]. |
G-EIS.8 | The EIS shall provide an electron beam to the ESR having RMS Bunch lengths at extraction to meet beam requirements as set forth in [5.9]. |
G-EIS.10 | The ESR bunch replacement pattern will be defined by 1.the required polarization pattern to be provided to the experiments, 2.decay rates and 3. The RF cogging limitations of the beam transfer between RCS and ESR. |
Children | |
P-EIS-GUN-INST-SR.1 | In the gun diagnostic line an electrostatic bend spin rotator (based on Illinois Univ. design, 1993) shall be used |
P-EIS-GUN-INST-SR.2 | The system shall include two High voltage power supplies and two HV cables |
P-EIS-GUN-INST-SR.3 | When bending at 300 keV the system shall have a bend angle of 143 deg |
P-EIS-GUN-INST-SR.4 | The system shall be able to bend the electron spin such that the direction after bending is horizontal |
P-EIS-GUN-INST-SR.5 | The system shall be able to bend the beam over the range of electron beam energies from 280 to 350 KeV |