Record Date: 02/04/2025 17:22 | |||
Identifier: | P-EIS-GUN-INST-SR.03 | WBS: | 6.03.04.02.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | On Hold | |
Description: | When bending at 300 keV the system shall have a bend angle of 143 deg | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | P-EIS-GUN-INST-SR.3 | WBS: | 6.03.04.02.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | When bending at 300 keV the system shall have a bend angle of 143 deg | ||
Comments: |
Parents | |
F-EIS-GUN-INST.5 | The Diagnostic beamline section shall have one Beam Profile Monitor and Wien Filter and an electrostatic bender before the Mott polarimeter and Faraday Cup. |
F-EIS-INST.1 | EIS shall have all the beam instrumentation necessary to deliver the operational parameters set forth in the MPT. [Document#:EIC-SEG-RSI-005] |
F-EIS-PREINJ-GUN.21 | The diagnostic beamline solenoids shall be capable of maintaining the beam size in the diagnostic line up to either the Faraday cup or the Mott polarimeter. |
F-EIS-TLINE-GUN-Diagnostic.1 | The Pre-injector separate diagnostic beamline section shall have 3 branches one with Faraday cup, one port containing a connection to the cathode Laser and a line to a low energy beam dump. |
F-EIS-TLINE-GUN-INST-Diagnostic.1 | The instrumentation in the diagnostic beamline to the low energy beam dump shall have the capability to measure beam position, profile, bunch charge |
Children | |
No children. |