Record Date: 10/10/2024 14:48 | |||
Identifier: | P-EIS-GUN-INST-F_CUP.1 | WBS: | 6.03.04.02.06 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | In Process | |
Description: | The Faraday cup shall be able to measure the charge of the electron bunches from the gun over a charge range of 0.1 - 14 nC | ||
Comments: |
No archive versions
Parents | |
F-EIS-GUN-INST.1 | The Diagnostic beamline section shall be able to measure the electron polarization using a suitable polarimeter |
F-EIS-GUN-INST.3 | The instrumentation in the diagnostic beam line shall have the capability to measure beam position, profile, bunch charge and beam halo. |
F-EIS-GUN-INST.2 | The Pre-Injector separate diagnostic beam line section shall have 3 branches one with a Mott polarimeter & Faraday cup, one containing a connection to the cathode Laser and a line to a low energy beam dump. |
F-EIS-GUN-INST.7 | The Faraday cup shall be able to measure the charge of the electron bunches from the gun. |
F-EIS.8 | EIS shall have all the beam instrumentation necessary to deliver the operational parameters set forth in [5.9]. |
Children | |
No children. |