Description: | The electromagnetic calorimeter in the central detector shall be capable of providing a resolution of s(E)/E ~ 10%/sqrt(E) + (1-3)% in the barrel and forward region and s(E)/E ~ 2%/sqrt(E) + (1-3)% in the backward region. | ||
Comments: |
Record Date: 02/25/2025 20:15 | |||
Identifier: | P-DET.3 | WBS: | 6.1 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The electromagnetic calorimeter in the central detector shall be capable of providing a resolution of s(E)/E ~ 10%/sqrt(E) + (1-3)% in the barrel and forward region and s(E)/E ~ 2%/sqrt(E) + (1-3)% in the backward region. | ||
Comments: |
Record Date: 02/24/2025 18:26 | |||
Identifier: | P-DET.3 | WBS: | 6.10 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The electromagnetic calorimeter in the central detector shall be capable of providing a resolution of s(E)/E ~ 10%/sqrt(E) + (1-3)% in the barrel and forward region and s(E)/E ~ 2%/sqrt(E) + (1-3)% in the backward region. | ||
Comments: |
Record Date: 02/13/2025 19:28 | |||
Identifier: | P-DET.3 | WBS: | 6.1 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The electromagnetic calorimeter in the central detector shall be capable of providing a resolution of s(E)/E ~ 10%/sqrt(E) + (1-3)% in the barrel and forward region and s(E)/E ~ 2%/sqrt(E) + (1-3)% in the backward region. | ||
Comments: |
Record Date: 01/27/2025 16:43 | |||
Identifier: | P-DET.3 | WBS: | 6.10 |
Date Modified: | TBD: | FALSE | |
Status Date: | Status: | Approved | |
Description: | The electromagnetic calorimeter in the central detector shall be capable of providing a resolution of s(E)/E ~ 10%/sqrt(E) + (1-3)% in the barrel and forward region and s(E)/E ~ 2%/sqrt(E) + (1-3)% in the backward region. | ||
Comments: |
Parents | |
F-DET.2 | The EIC central detector shall cleanly identify the electron-quark and electron-gluon scattering process to high efficiency by a combination of tracking, particle identification detectors and calorimeters. |
Children | |
No children. |
This function not yet implemented.