Record Date: 07/14/2023 00:00 | |||
Identifier: | P-DET-TRAK-BAR.3 | WBS: | 6.10.03 |
Date Modified: | 07/14/2023 00:00 | TBD: | FALSE |
Status Date: | 07/14/2023 00:00 | Status: | APPROVED |
Description: | The barrel tracking system shall provide a spatial resolution of σxy ∼ 20/pT ⊕ 5 μm in the rapidity region between -1 to 1. | ||
Comments: |
Record Date: 07/14/2023 00:00 | |||
Identifier: | P-DET-TRAK-BAR.3 | WBS: | 6.10.03 |
Date Modified: | 07/14/2023 00:00 | TBD: | FALSE |
Status Date: | 07/14/2023 00:00 | Status: | APPROVED |
Description: | The barrel tracking system shall provide a momentum resolution of σp/p ~ 0.05%?p+0.5% in the rapidity region between -1 to 1. | ||
Comments: |
Parents | |
F-DET-TRAK.3 | The tracking system must provide good impact parameter resolution for heavy flavor measurements. |
Children | |
No parents. |